Check RH
Use a hygrometer if possible. If the room is already near target, lower water collection may be completely normal.
The most common causes are: room temperature below 65°F (coils cannot get cold enough), a dirty air filter restricting airflow, or the humidity setpoint is already above the current room RH. Check temperature first, then clean the filter, then verify the setpoint is at least 10% below room humidity.
If the unit is under warranty and the filter is clean, the room is warm, and the setpoint is correct but the unit still does not collect water — the compressor or refrigerant circuit may have failed. Get a repair quote. If the unit is over 5 years old and the repair estimate exceeds half the cost of a new unit, replacement is usually the better choice.
Coil frost happens when the room is too cold (below 65°F), the filter is clogged, or the fan speed is too low. Clean the filter first. If the room is cold, consider a low-temperature-rated model. If frost continues in a warm room with a clean filter, the refrigerant charge or fan may be faulty.
Washable filters: every 2 weeks during heavy use, monthly during moderate use. Carbon or odor filters: replace every 3–4 months. HEPA filters: replace every 6–12 months depending on runtime. A dirty filter is the number one cause of poor water collection.
Last reviewed: 2026-08. Information is periodically reviewed and updated as standards, testing procedures, and field data evolve.